Catégories
Endoscopie

To test or not to test? (Re)integration cultures improve microbiological safety in endoscopy: preliminary results of a prospective study

2026

1- Gonçalo Silva
2- Ricardo Cardoso
3- Paula Cruz
4- Carla Almeida
5- Helena Loureiro
6- Carla Regalo
7- Francisco Neves
8- Ângela Domingues
9- Hugo Sousa
10- Rute Gomes
11- Eugénia Cancela
12- Paula Sousa
13- Diana Martins
14- Ana Catarina Carvalho
15- Francisco Pires
16- Ricardo Araújo
17- António Castanheira
18- Luísa Soares
19- Américo Silva
20- Paula Ministro


Endoscopie – 27/04/2026 – Communication orale

Introduction
Microbiological surveillance of endoscopic devices is typically conducted through scheduled routine cultures. In our endoscopy unit, an additional “(re)integration culture” protocol is performed via systematic sampling of devices upon return from external maintenance or upon initial delivery as a standard operational practice. This protocol has not previously been evaluated in a prospective manner to determine whether this additional sampling at the moment of endoscope (re)integration increases detection of contamination compared with only routine surveillance.

Aims & Methods
The aim of this study was to perform a comparative analysis of positivity rates between “(re)integration” and “routine” cultures and to describe the microbiological and operational characteristics of positive cases. In a prospective database, we recorded all microbiological analysis from endoscopes entering service in our unit from January 2020 to July 2025 until the first positive result. These included not only “routine” cultures, but also “(re)integration” cultures (following the first admission and every external maintenance). Positive scopes were also re-tested until the first negative result, after which no further data were recorded.
Collected variables comprised the type of endoscope, culture protocol, culture result, time to positivity, isolated organism, contamination site, number of reprocessing cycles to negativity, and quarantine duration. Appropriate statistical tests were applied, and results were considered statistically significant when p<0.05. Results A total of 202 cultures were included [121 (re)integration; 81 routine]. (Re)integration cultures returned 19/121 positives (15.7%) versus 4/81 positives (4.9%) for routine cultures (p = 0.023). All positive devices required a single extra reprocessing cycle to achieve negativity, with a mean quarantine duration of 6.3 ± 1.6 days. The most frequently isolated organisms were Gram-positive rods (47.8%). Contamination was most commonly located in the suction channel (60.9%). The median time to first contamination was 20 months (IQR 31). The median number of repairs up to the first contamination was 1 repair (IQR 3). Conclusion These results indicate that (re)integration cultures detect significantly more contaminations than scheduled routine cultures. Sampling at the time of device integration is therefore a critical intervention point for microbiological surveillance. This study supports the value of (re)integration cultures as part of endoscope quality assurance. This is an ongoing study and confirmation with larger datasets and complementary analyses is planned. References • Reprocessing of flexible endoscopes and endoscopic accessories used in gastrointestinal endoscopy: Position Statement of the European Society of Gastrointestinal Endoscopy (ESGE) and European Society of Gastroenterology Nurses and Associates (ESGENA) – Update 2018. DOI https://doi.org/10.1055/a-0759-1629.